Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Endourology(Electronic Edition) ›› 2023, Vol. 17 ›› Issue (06): 642-646. doi: 10.3877/cma.j.issn.1674-3253.2023.06.018

Special Issue:

• Experiment Research • Previous Articles     Next Articles

Feasibility study of EDGE SP1000 single hole surgical robot assisted laparoscopic partial ureterectomy with end-to-end anastomosis in pigs

Cheng Liu, Cong Lai, Jian Huang, Jianchen Wang, Xiyun Luo, Kewei Xu()   

  1. Department of Urology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou 510120, China
    Shenzhen Jingfeng Medical Technology Co., LTD., Guangdong 518100, China
  • Received:2023-10-17 Online:2023-12-01 Published:2023-11-23
  • Contact: Kewei Xu

Abstract:

Objective

To evaluate the safety and feasibility of using the EDGE SP1000 single-port surgical robot for laparoscopic partial ureterectomy with end-to-end anastomosis in a live pig model.

Methods

The EDGE SP1000 single-port robotic surgical system was used to perform laparoscopic partial ureterectomy with end-to-end anastomosis in pigs. Vital signs of the pigs were monitored during the surgery, and surgical difficulties and complications were recorded. The survival of the pigs was observed for two weeks post-operatively.

Results

All pigs survived for two weeks after the surgery, with no surgical complications or technical difficulties encountered during the procedure. The average time for establishing the surgical access in five pigs was (15.0±1.2) min, while the installation time for the EDGE SP1000 single-port surgical robot system was also (5.6±0.6) min. The time for ureterectomy was (8.8±1.3) min, the time for end-to-end anastomosis of the ureter was (39.2±2.3) min, and the total surgical time was (89±5) min, and intraoperative blood loss was (1.20±0.24) mL. The surgical team highly praised the performance of the surgical system.

Conclusion

This study confirms that the EDGE SP1000 single-port robotic surgical system is safe and feasible for laparoscopic partial ureterectomy with end-to-end anastomosis in pigs. The next step is to evaluate the safety and effectiveness of the EDGE SP1000 system in other surgical procedures, providing more reliable preclinical data support.

Key words: Single-port surgical, robot, Robotic-assisted laparoscopy, Partial ureterectomy, End-to-end anastomosis, Live pig

京ICP 备07035254号-20
Copyright © Chinese Journal of Endourology(Electronic Edition), All Rights Reserved.
Tel: 020-85252990 E-mail: chinendourology@126.com